Remote Sensor for Gaslab Multi-Gas Detector
Remote Sensors for the Gaslab Multi-Gas Detector designed to measure combustible, toxic gases and oxygen as well as refrigerants. The remote sensors can only be operated in conjunction with the sensor boards on the MSC2 Gaslab Multi Gas Detectors. These remote sensors can not be used in potentially explosive atmospheres and must only be employed in areas within the environmental conditions as specified by the manufacturer.
Features
- Internal functional control with integrated watchdog
- Easy maintenance//calibration by exchange of the sensor or on-site calibration
- High Accuracy, selectivity and reliability
- Low zero-point drift
- Sensor with long life expectancy (dependent upon gas)
- Hardware and software according to SIL compliant development process
- 4-20mA (or 2-10V) analog output with selectable signal output for special mode (fault, maintenance, service, et)
- Reverse polarity protected, overload and short-circuit proof
- IP65 protection (when installed)
Specifications
- Measurement Range: Dependent upon sensor selected
- Gas Type: Dependent upon sensor selected
- Housing Type C/E: Type A, Polycarbonate
- Installation: Wall Mounted
- Knockouts for Integration of SC2: 3x M25 for M25 housing
- Protection Class: NEMA 4X (IP 65)
-
Temperature Range: -35 °C to +60 °C (-31 °F to 140 °F)
- Humidity Range: 15–90 % RH not-condensing
- Storage Temperature: -20 °C to +65 °C (-4 °F to 149 °F)
-
Power Supply:
- 16–29 V DC, reverse-polarity protected 24 V AC ± 15 % (only 1x SC2 connected, not for DGC-06 mode)
- Power Consumption: 10 mA (0.24 VA)
- Output for Local Bus: 5 V DC, 250 mA max. Overload, short-circuit and reverse-polarity protected
- Overvoltage Category: I
- Permissible Height Above Sea Level: 1500 m (ca. 5000 ft.)
-
Wire connection: Field bus Local bus for SC2:
- Screw-type terminal 0.25–2.5 mm2 (24–10 AWG) 3-pin connector
- Cable lengths local bus for Remote Board: Max. 16.4 ft. (5 m)
- Dimensions: 3.7 x 5.1 x 2.2 in. (94 x 130 x 57 mm)
- Weight: 0.7 lb. (0.3 kg)
Warranty
- 1 year - See CO2Meter Terms and Conditions.
Options
- MC2-0-E1110-A-0-P l CO Analog Sensor for Gaslab Fixed Gas Detector (0-50ppm CO)
- MC2-0-E1125-A-0-P l NH3 Analog Sensor for Gaslab Fixed Gas Detector (0-100ppm NH3)
- MC2-0-E1130-B-0-P l NO2 Analog Sensor for Gaslab Fixed Gas Detector (0-20ppm NO2)
- MC2-0-E1194-A-0-P l H2 Analog Sensor for Gaslab Fixed Gas Detector (0-1000ppm H2)
- MC2-0-E1195-A2-0-P l O2 Analog Sensor for Gaslab Fixed Gas Detector (0-25% O2)
- MC2-0-I464-B-0-P l CO2 Analog Sensor for Gaslab Fixed Gas Detector (0-5% CO2)
- MC2-0-E1197-B-0-P l H2S Analog Sensor for Gaslab Fixed Gas Detector 0-100ppm
-