Fixed Multi-Gas Detector

Fixed Multi-Gas Detector
Precio habitual $1,140.00

POs or wholesale quantity discounts click here

The Fixed Multi-Gas Detector is designed to protect individuals near toxic, combustible, and hazardous gases, or oxygen in commercial and industrial applications. This detector can activate alarm relays, display real-time measurements, and connect with any Building Maintenance System (BMS).

This Gaslab Fixed Multi-Gas Detector can monitor up to 1-3 gases across ammonia, carbon dioxide, carbon monoxide, hydrogen, oxygen, and more. With 3 configurable relays and audible/visual alarms the MSC2 meets most gas safety code requirements, standards, and conformities.

Features

  • Modular easy-to-use design
  • 1-3 gas sensor capabilities
  • 3 configurable relays
  • 2 sensors max may be different sensors of the SC2 series, max 3 of them analog with  4-20 mA signals
  • Custom configuration dependent upon location and application
  • Warning buzzer/LED alarm, fault + operation option
  • Compatible with a wide range of BMS
  • Protocol for DGC-06 or Modbus protocol
  • Operating voltage input 100-240 VAC or 24VDC

Specifications

  • Measurement Range: Dependent upon gas sensors selected
  • Gas Type: Dependent upon gas sensors selected
  • Housing Type C/E: Polycarbonate
  • Installation: Wall Mounted
  • Knockouts for Cable Entry: Standard 6x M20/25
  • Ingress Protection: IP65
  • Temperature Range: -13°F to 140°F (-30°C to 50°C)
  • Humidity Range: 15-90% RH non-condensing
  • Storage Temperature: -4°F to 149°F (0° to 20°C)
  • Power Supply: 100-240 VAC or 24VDC
  • Power Consumption: 24 V DC | Max. 60 mA (1.5 VA), w/ sensor, w/o WAO
  • Alarm Relay (3): 5 A Dry Contact Configurable
  • Transistor Output (2): 24 V DC/0.1 A
  • Analog Input (2/3): 4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range
  • Analog Output Signal (1):
    • 2.4–< 4 mA = tolerable under range
    • 20–21.2 mA = tolerable over range 
    • ≥ 21,2 mA= error over range
    • ≤ 2,0 mA = fault
  • Dimensions: 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
  • Weight: 1.32 lbs. (0.6 kg)

Warranty

  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...