🎄 Please Note: CO2Meter offices will be closed for the upcoming Holiday, 12/23-12/25, we will return refreshed and ready to serve you at 8:30AM ET on 12/26. We wish those celebrating a very Merry Christmas and a Happy New Year! 🎄

TecMicro 0-100% Oxygen O2 Sensors

TS-401 Oxygen Trace Gas: 0-2000 ppm l CO2Meter
Precio habitual $3,299.00

POs or wholesale quantity discounts click here

TecMicro Oxygen Sensors are optochemical gas sensors that can measure oxygen levels from a few parts per billion to 100% O2 by volume in ambient air or in liquid depending on the model. This makes them useful for breweries, modified atmosphere packaging, testing head-space gases, bio-incubators, respirometers, algae or aquatic applications. It can even measure the oxygen level in a fish tank or a tank of gasoline.

Features

  • Measure oxygen level in gas or liquid models
  • Measure from 0ppb to 100% oxygen (depends on model)
  • Optical sensor not sensitive to hydrogen or CO2
  • Fast and accurate
  • ATEX II approved for use in explosive atmospheres

Because it is all stainless steel, the TecMicro Oxygen Sensors can be used in clean in place (CIP) and sterilize In place (SIP) applications like incubation, brewing, or in the pharmaceutical or food processing industries. The sensor can withstand high temperature, high pressure, cleaning agents and anti-bacterial compounds.

The ability to measure 0% oxygen levels means that it can be used to measure dew point to determine if you have dry gas - important in welding and other metallurgy applications.

Models

All models listed below come with an RS485 to USB connector and 5VDC adapter so that the sensor can communicate directly with our free GasLab® software. 1/2" fine thread connector in stock. Other connectors available by request.

Gas Models

TS-401: Trace: 0-2,000 ppm
TS-402: Low: 0-5% *
TS-403: Medium: 0-22%
TS-404High Range: 0-100%

    Liquid Models

    TS-405: Trace: 0-200 ppb
    TS-406: Low: 0-2,000 ppb (2 mg/L) *
    TS-407: Medium: 0-10 mg/L *
    TS-408High Range: 0-40 mg/L *

    TS-101: Stainless Steel 1/2" Calibration Gas Tee (works with all models).

    * Special Order

    Specifications - All

    • Dimensions: 12mm x 60mm (½“-connector)
    • Temperature range: -10°C-60°C  (14°F-140°F)
    • Average LED Lifetime 10,000+ hours
    • Data Interface: RS485 non Modbus
    • Temperature compensation: -4°C-40°C  (39°F-104°F)
    • Pressure compensation: STP by default. Change in software.
    • Data Output: digital USB or RS485 non Modbus
    • Cleaning: No organic solvents, 40% EtOH
    • Materials touching sample: St.1.4404/PTFE/Glass
    • Connection: ½“ stainless steel hex nut
    • Protection: IP65
    • Sensor cap replacement interval: 12 months or more
    • Recommended zero-point calibration interval: 3 months
    • Manufacturer's recommended service interval: 3 years

    Specifications - Models

    TS-401 Trace Gas: 0-2,000 ppm

    • Accuracy 0-100 ppm: ± 2% MEV
    • Accuracy 100-1000 ppm: ± 3% MV
    • Accuracy 1000-2000 ppm: ± 4% MV
    • Resolution: 1 ppm
    • Response Time at 25°C: <15s
    • Max. Pressure: 5 bar
    • Expected cap lifetime: 1 year

    TS-403 Standard: 0-220,000 ppm (22%)

    • Accuracy 0-5%: ± 2% Mev
    • Accuracy 5-15%: ± 3% Mev
    • Accuracy 15-22%: ± 3% Mev
    • Resolution: 0.001%
    • Response Time at 25°C: 5s w/o protective layer
    • Max. Pressure: 5 bar
    • Expected cap lifetime: 2 years 

    TS-404 High Range: 0-100%

    • Accuracy 0-5%: ± 3% MEV
    • Accuracy 5-22%: ± 4% MV
    • Accuracy 22-100%: ± 5% MV
    • Resolution: 0.001%
    • Response Time at 25°C: 0.5s w/o protective layer
    • Max. Pressure: 5 bar
    • Expected cap lifetime: 2 years 

    TS-405 Trace Liquid: 0-200 ppb

    • Accuracy: 0-200ppb: ± 2% MEV
    • Resolution: 1ppb
    • Response Time at 25°C: <20s 
    • Max. Pressure: 20 bar
    • Expected cap lifetime: 1 year

    TS-408 High Range: 0-40 mg/L

    • Accuracy: 0-2 mg/L: ± 3% MEV
    • Accuracy: 2-8 mg/L: ± 4% MV
    • Accuracy: 8-10 mg/L: ± 4% MV
    • Accuracy: 10-40 mg/L: ± 5% MV
    • Resolution: 0.001 mg/L
    • Response Time at 25°C: <20s
    • Max. Pressure: 20 bar
    • Expected cap lifetime: 2 years

    - MEV = Measured end value
    - MV = Measured value

    Dissolved Liquid Cross Sensitivity

    While the TecMicro is monoscopic (low cross-sensitivity) to other gases, dissolved oxygen sensors can be sensitive to the following:

    • Alcohols greater than 5%
    • Hydrogen peroxide (H2O2) greater than 3%
    • Sodium hypochlorite (NaClO, commercial bleach) greater than 3%
    • Gaseous sulfur dioxide (SO2) or chlorine (CL2)

    If the measurements are unstable and other troubleshooting procedures do not correct the problem, there may be interfering substances present in the solution.

    There is no interference from the following:

    • Carbon dioxide (CO2)
    • Ammonia (NH3)
    • pH, or any ionic species like sulfide (S2 -), sulfate (SO4-2), chloride (Cl-)
    • Hydrogen sulfide (HS-)

    Warranty

    • 1 year. See GasLab terms and conditions.

    The TecMicro comes with a free software utility that allows you to graph the oxygen level over time, to save your data, to calibrate the sensor, and to update the calibration when a new sensor cap is installed.

    TecMicro TecService Software (zip)

    System Requirements

    • Windows XP SP2 or newer
    • Microsoft .Net 3.5 Runtime Libraries

    • Data Sheets

    • Manuals

    • Technical Documents

    • Videos

    • Additional Resources

    • Case Studies

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    "Easy to install, easy to set up, and easy calibration - just what I was looking for."

    - Phillip Farrar
    Water Plant Superintendent

    Read More Reviews...