🎄 Please Note: CO2Meter offices will be closed for the upcoming Holiday, 12/23-12/25, we will return refreshed and ready to serve you at 8:30AM ET on 12/26. We wish those celebrating a very Merry Christmas and a Happy New Year! 🎄

AM1002 PM, VOC, Temp, and RH Sensor

AM1002 PM, VOC, Temp, and RH Sensor
Regular price $80.78

POs or wholesale quantity discounts click here

AM1002 Integrated IAQ Sensor is an indoor air quality sensor that measures particle concentration, VOC concentration, temperature and relative humidity. This makes it useful as an all-in-one solution for measuring IAQ.

Particle concentration is measured by a laser particle sensor which uses the light scattering principle. The sensor measures and calculates the suspended particles and outputs the particle mass concentration μg/m3 directly.

The VOC sensor is MOX type, which has extremely high sensitivity to various kinds of organic volatile gases such as formaldehyde, benzene, ethanol, formic acid, nicotine and some inorganic gas like carbon monoxide, ammonia, hydrogen.

Features

  • Three-Channel Output - PM1.0, PM2.5, PM10
  • Auto Particle Identification allows the sensor to "switch" between calibration algorithms based on changing application needs
  • Matrix calibration provides high accuracy throughout the working temperature and measurement range
  • Constant speed fan and constant power diode maintain measurement accuracy and stability

Models

AM1002 - IAQ Sensor - integrates particle concentration, VOC concentration, temperature and relative humidity measurement in a single package.

Specifications

  • Operating principle: Laser scattering for PM, MOX for VOC measurement
  • Measurement range (PM): 0~5,000μg/m³
  • Measurement range (VOC): 0~10ppm
  • Measurement range (Temp): -20-70℃
  • Measurement range (Humidity): 0-99%RH
  • Measured particle range: 0.3μm~10μm
  • Particle output resolution: Particle output resolution
  • VOC output resolution: 1 ppb
  • Temperature output resolution: 0.1℃
  • Humidity output resolution: 0.1%
  • Working condition: -20°C ~ 60°C, 0-95%RH (non-condensing)
  • Storage condition: -40°C ~ 80°C, 0-95%RH (non-condensing)
  • Particle accuracy: PM1.0/PM2.5: 0~100μg/m3 : ±10μg/m³ 101~500μg/m3 : ±10% reading PM10: 0~100μg/m3 : ±25μg/m³ 101~500μg/m3 : ±25% reading (GRIMM, 25±2℃, 50 ±10%RH
  • Temperature accuracy: 0°C ~ 40°C: ±1°C
  • Humidity accuracy: Typical/Max: ±5%/±8% @5%-95%RH
  • VOC Consistency: Typical/Max: 200ppb/250ppb OR 20%/25%
  • Sampling interval: Particle sampling: 1s VOC
  • Temperature & Humidity: 10.5s
  • Response time: VOC: ≤ 180 seconds; Particle: ≤ 8 seconds; RH&T: ≤ 8 seconds
  • Power supply: DC 5V±0.1V, ripple wave<50mV
  • Working current: ≤100mA
  • Standby current: ≤200μA 
  • Dimensions: 38 x 35 x 12 mm
  • Lifespan: >10 years

Warranty



  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...