Digital Multi-Gas Controller System
The DGC-06: Digital Multi-Gas Controller System is used for the monitoring and warning of toxic and combustible gases and vapors, as well as refrigerants within a wide range of gas measurements.
The controller system is designed to monitor and manage up to 128 gas options, 96 digital sensors, and 32 analog sensor options. The controller series also provides 4 free adjustable alarm thresholds with each provided sensor.
The DGC-06 also meets most gas safety code requirements, standards, and conformities along fulfilling current EN50545-1 CO monitoring, EN 378, VBG 20 NH3 monitoring and more.
*This digital multi-gas controller system ONLY works in conjunction with our Fixed Multi-Gas Detector Series or Combustible Fixed Gas Detectors.*
Features
- Modular, easy to use, for large facilities
- 128 gas sensor capabilities
- 4 free adjustable alarm thresholds per sensor
- 5 menu languages, free adjustable settings
- Several alarm relays configurable per alarm
- Alarm release by falling or increasing gas concentrations
- Connector for PCE06 Software at the controller module
- Flexible configuration and programmable parameters/set points
- Warning buzzer/LED alarm, fault + operation option
- Compatible with a wide range of BMS
- SIL2 Level Compliant
Specifications
- Measurement Range: Dependent upon gas sensors selected
- Gas Type: Dependent upon gas sensors selected
- Housing Type C/E: Plastic Housing with View Cover
- Installation: Wall Mounted
- Knockouts for Cable Entry: Standard 6x M20/25
- Ingress Protection: IP65
-
Temperature Range: 23 °F to 104 °F (-5 °C to +40 °C)
- Storage Temp Range: 32 °F to 104 °F (0°C to +40°C)
- Humidity Range: 15-95% RH non-condensing
- Power Supply: 90/230 V AC, 50/60 Hz; 24VDC ± 20 %
- Power Consumption: Min. 30W, 0.15A, max. ca. 160W, 0.7A, depending on type
-
Analog Input (4 to max. 32): 4–20 mA, overload and short-circuit proof, input resistance 130µ
- Tension for external analog transmitter: 24VDC ±20 %, max130mA - per sensor
-
Analog output (max 16) configurable for each input:
- Proportional, overload and short-circuit proof, charge ≤ 500µ
- 4–20 mA = measuring range
- 3.0–<4 mA = under range
- > 20–21.2 mA = over range
- 2.0 mA = fault
- Relay (max. 32): 250 VAC, 5 A; 30 V DC, 2 A, potential-free, change-over (SPDT)
- Fault relay (1): 250VAC, 5A; 30VDC, 2A, potential-free, normally open contact (SPST)
-
Menu Language (selectable): German, English, French, or Italian
-
Transceiver: RS485 / 19200 Baud
- Dimensions: W x H x D - 11.7 x 10.2 x 5.5 in. | (298 x 260 x 140 mm)
- Weight: Min. 4.4 Ib. (2.7 kg), max. 28.7 Ibs. (13 kg) depending on type
- Weight: 1.32 lbs. (0.6 kg)
Regulations
- EMC Directive 2014/30/EU
- Low Voltage Directive 2014/35/EU
- EN 50271
- EN 61010-1:2010
- ANSI/UL 61010-1
- CAN/CSA-C22.2 No. 61010-1
- EN 50545-1
Warranty
- 1 year - See CO2Meter Terms and Conditions.
Options
- MSC-2 | Multi-Gas Fixed Gas Detector
- SC2-E1110-A-P-00 | CO Digital Sensor for MSC2
- SC2-E1130-B-P-00 | NO2 Digital Sensor for MSC2
- SC2-E1194-A-P-00 | H2 Digital Sensor for MSC2
- SC2-E1195-A2-P-00 | O2 Digital Sensor for MSC2
- SC2-I464-B-P-00 | CO2 Digital Sensor for MSC2
Looking for More? View our full list of gas sensor capabilities and options here
-
Data Sheets
-
Manuals
-
Technical Documents
-
Videos
-
Additional Resources
-
Case Studies