**CO2Meter will be closed for the Thanksgiving holiday at 5:00pm et., on 11/27. We will reopen at 8:30am et., 12/1.

🎁 Also, Save BIG this Holiday - use code "SENSE" at checkout for 10% OFF! Valid through 12/3!🎄 >> Shop All Products << **

Remote Sensor for Gaslab Multi-Gas Detector

Remote Sensor for Gaslab Multi-Gas Detector
Regular price €513,02

POs or wholesale quantity discounts click here

Remote Sensors for the Gaslab Multi-Gas Detector designed to measure combustible, toxic gases and oxygen as well as refrigerants. The remote sensors can only be operated in conjunction with the sensor boards on the MSC2 Gaslab Multi Gas Detectors. These remote sensors can not be used in potentially explosive atmospheres and must only be employed in areas within the environmental conditions as specified by the manufacturer.

Features

  • Internal functional control with integrated watchdog
  • Easy maintenance//calibration by exchange of the sensor or on-site calibration
  • High Accuracy, selectivity and reliability
  • Low zero-point drift
  • Sensor with long life expectancy (dependent upon gas)
  • Hardware and software according to SIL compliant development process
  • 4-20mA (or 2-10V) analog output with selectable signal output for special mode (fault, maintenance, service, et)
  • Reverse polarity protected, overload and short-circuit proof
  • IP65 protection (when installed)

Specifications

  • Measurement Range: Dependent upon sensor selected
  • Gas Type: Dependent upon sensor selected
  • Housing Type C/E: Type A, Polycarbonate
  • Installation: Wall Mounted
  • Knockouts for Integration of SC2: 3x M25 for M25 housing
  • Protection Class: NEMA 4X (IP 65) 
  • Temperature Range: -35 °C to +60 °C (-31 °F to 140 °F)
  • Humidity Range: 15–90 % RH not-condensing 
  • Storage Temperature: -20 °C to +65 °C (-4 °F to 149 °F) 
  • Power Supply:
    • 16–29 V DC, reverse-polarity protected 24 V AC ± 15 % (only 1x SC2 connected, not for DGC-06 mode)
  • Power Consumption: 10 mA (0.24 VA) 
  • Output for Local Bus: 5 V DC, 250 mA max.  Overload, short-circuit and reverse-polarity protected 
  • Overvoltage Category: I
  • Permissible Height Above Sea Level: 1500 m (ca. 5000 ft.) 
  • Wire connection: Field bus  Local bus for SC2:
    • Screw-type terminal 0.25–2.5 mm2 (24–10 AWG) 3-pin connector  
  • Cable lengths local bus for Remote Board: Max. 16.4 ft. (5 m)
  • Dimensions:  3.7 x 5.1 x 2.2 in.  (94 x 130 x 57 mm)
  • Weight: 0.7 lb. (0.3 kg)

Warranty

  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...