**CO2Meter will be closed for the Thanksgiving holiday at 5:00pm et., on 11/27. We will reopen at 8:30am et., 12/1.

🎁 Also, Save BIG this Holiday - use code "SENSE" at checkout for 10% OFF! Valid through 12/3!🎄 >> Shop All Products << **

Oxygen (O2) Fixed Gas Detector w/ Remote Sensor (0-25%)

MSC2_MC2-0-E1195-A2-0-P-Fixed-O2-Detector-with-Remote-co2meter
Regular price $1,969.00

POs or wholesale quantity discounts click here

The Oxygen (O2) Fixed Gas Detector w/ Remote Sensor (MSC2 + MC2-0-E1195-A2-0-P) is designed to protect individuals near toxic gases like oxygen, nitrogen, or helium in commercial and industrial applications. This fixed gas safety monitor measures 0-25% O2 levels and detects hazards in order to protect facilities from overexposure.

Fixed oxygen gas detectors are critical in scientific, medical, manufacturing and industrial applications - or anywhere O2 is being used, stored, or produced. 

Features

•    Modular easy-to-use design, 1-3 gas sensors
•    Custom configuration dependent upon application
•    Warning buzzer/LED alarm, fault + operation option
•    Includes Separate Remote Gas Sensor to be placed near Hazard Location 
•    Compatible with a wide range of BMS
•    3 configurable relays
•    2 digital/analog sensor inputs (configurable)
•    Protocol for DGC-06 or Modbus protocol
•    Operating voltage input 100-240 VAC or 24VDC

Specifications

  • Measurement Range: 0-25%
  • Gas Type: Oxygen (O2)
  • Housing Type C/E: Polycarbonate
  • Installation: Wall Mounted
  • Knockouts for Cable Entry: Standard 6x M20/25
  • Ingress Protection: IP65
  • Temperature Range: -13°F to 140°F (-25°C to 60°C)
  • Storage Temperature: -4°F to 149°F (-20°C to 65°C)
  • Humidity Range: 15-95% RH non-condensing
  • Power Supply: 100-240 VAC or 24VDC
  • Power Consumption: 24 V DC | Max. 60 mA (1.5 VA), w/ sensor, w/o WAO
  • Alarm Relay (3): 5 A Dry Contact Configurable
  • Transistor Output (2): 24 V DC/0.1 A
  • Analog Input (2/3): 4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range
  • Analog Output Signal (1):
    • 2.4–< 4 mA = tolerable under range
    • 20–21.2 mA = tolerable over range 
    • ≥ 21,2 mA= error over range
    • ≤ 2,0 mA = fault
  • Dimensions: 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
  • Weight: 1.32 lbs. (0.6 kg)

Warranty

  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...