**CO2Meter will be closed for the Thanksgiving holiday at 5:00pm et., on 11/27. We will reopen at 8:30am et., 12/1.

🎁 Also, Save BIG this Holiday - use code "SENSE" at checkout for 10% OFF! Valid through 12/3!🎄 >> Shop All Products << **

News

Temperature Change Impacts Oxygen Sensors

Temperature Change Impacts Oxygen Sensors

If you work with gases like we do at CO2Meter, you already know that the ideal gas law PV=nRT shows that absolute gas concentration decreases as temperature increases. This relationship is important to anyone measuring oxygen levels during combustion, fermentation, distillation or algae production. But like they say, “a picture is worth a thousand words.” That’s what we discovered when we measured the change in oxygen gas levels in a sealed environment using our UVFlux 25% Oxygen sensor and Gaslab software. Using the built-in RS232 protocol, the UVFlux sensor samples both the oxygen level and the temperature inside the sensor...

Read more →


Constant CO2 Level in Greenhouse

  Controlled CO2 gas inflow and improved air mixture can help maintain optimum CO2 levels in small indoor greenhouses or grow rooms. These were the lessons learned after working with a client who was attempting to control the CO2 levels in a group of 3 10x20” greenhouses. The client wanted to maintain different consistent CO2 levels in each greenhouse to test the effects on the plants inside. To control the CO2, he used our iSense 1% CO2 Level Controller, a more industrial version of our Day Night CO2 Monitor & Controller for Greenhouses. In one test greenhouse, the CO2 controller...

Read more →


Gas Sensor Response Time Increases with Length of Tubing

Gas Sensor Response Time Increases with Length of Tubing

CO2 sampling sensors in a react at different rates depending on the length of the tubing used between the source gas and the sensor.In a closed loop system.

Read more →


Senseair CO2 Sensor Pressure Dependence

All infrared (NDIR) CO2 sensors have a dependence on pressure. This is because of the physics principle used to measure CO2 concentration. The NDIR type of sensor measures the IR radiation absorbed by CO2 molecules, which corresponds to the mole concentration. When pressure increases, the number of molecules in a given volume also increases linearly. Conversely, when pressure decreases (higher altitudes, for example) the number of molecules decrease. This app note includes both general information about Senseair sensors and pressure, as well as the equation for computing true CO2 level readings at various pressures useful for any NDIR CO2 sensor....

Read more →


Methane Sensor Used in Science Fair Project

Methane Sensor Used in Science Fair Project

Which animal waste has the potential to produce the most methane? That was the question posed by Sean Weiss in his “Waste to Watts” science fair project that won the Orange County Science Fair for Alternative Energy. Sean, who currently attends middle school in California, said the idea for the project first occurred to him while he was cleaning up after the family dog. “Before starting this experiment, on one of our family trips I learned that some cow farms in the northern part of the Central California basin were using some of the methane from the waste to power...

Read more →