AM1009 Integrated 5 in 1 IAQ Sensor

AM1009 Integrated 5 in 1 IAQ Sensor
Precio habitual €58,46

POs or wholesale quantity discounts click here

The AM1009 Integrated 5 in 1 IAQ Sensor is an integrated air quality sensor module that measures airborne particle concentration, VOCs, NO2 concentration, temperature and relative humidity. This makes it useful as an IAQ sensor for those who also want to measure nitrogen dioxide: a reddish-brown, acidic, corrosive, and pungent gas that is highly reactive and poisonous:

This IAQ sensor measures calculates the suspended particle number exactly, and outputs particle mass concentration μg/m3 directly via mathematical algorithm. 

VOC and NO2 concentration are measured by a combined MOX sensor, which can detect simultaneously. This sensor is also sought after due to its extremely high sensitivity to various kinds of organic volatile gases such as formaldehyde, benzene, ethanol, formic acid, nicotine and some inorganic gases like carbon monoxide, ammonia and hydrogen.

Features

  • 5 in 1 sensor module with integrated particle, VOC, NO2 and RH&T
  • Real time PM1.0 PM2.5 and PM10 output simultaneously
  • High accuracy, high sensitive and quick response
  • Temperature compensation algorithm
  • Matrix calibration technology and optimized algorithm, for high accuracy and consistency
  • Long lifespan and high stability

Models

AM1009 -  Integrated 5 in 1 IAQ Sensor - integrated air quality sensor module with particle concentration, VOC and NO2 concentration, temperature and relative humidity measurement.

Specifications

  • Measurement range: PM: 0~5000μg/m³; VOC: 0~10 ppm; NO2: 0-1000 ppb
  • Temperature: -20℃~70℃
  • Relative humidity: 0%~95%RH
  • PM accuracy: PM1.0/PM2.5: 0~100μg/m³: ±10μg/m³; 100~500μg/m³: ±10% of reading
    PM10: 0~100μg/m³: ±20μg/m³; >100μg/m³: ±20% of reading
    25℃±2℃, 50±10%RH, GRIMM, Cigarette + Arizona A1)
  • VOC accuracy: 160ppb or ±40% of reading, whichever is larger (25±2℃, 50 ±10%RH)
  • NO2 accuracy: 40ppb or ±40% of reading, whichever is larger (25±2℃, 50 ±10%RH)
  • Temperature accuracy: 0°C ~ 50°C: ±1°C
  • Humidity accuracy: 5%-95%RH: ±5%RH
  • Working condition: -10℃~50℃, 0~95%RH(non-condensing)
  • Storage condition: -30℃~70℃, 0~95% RH(non-condensing)
  • Power supply: DC 5V±0.1V; ripple wave <50mV
  • Working current: <105mA
  • Signal output: UART_TTL 
  • Dimensions: 50 x 38 x 21
  • Lifespan: >10 years

    Warranty



    • Data Sheets

    • Manuals

    • Technical Documents

    • Videos

    • Additional Resources

    • Case Studies

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    "Easy to install, easy to set up, and easy calibration - just what I was looking for."

    - Phillip Farrar
    Water Plant Superintendent

    Read More Reviews...