Fixed Ammonia (NH3) Gas Detector (0-100ppm)

MSC2 + SC2-E1125-A-P-00 l CO2Meter
Precio habitual €1.762,55

POs or wholesale quantity discounts click here

The Fixed Ammonia NH3 Gas Detector is designed to protect individuals near toxic and combustible gases, refrigerants, or oxygen in commercial and industrial applications. This fixed gas safety monitor measures NH3 levels between 0-100ppm and detects hazards in order to protect facilities from overexposure.

Fixed ammonia gas detectors are critical in pharmaceutical, petrochemical, poultry, indoor agriculture, and research applications - or anywhere NH3 is being used, stored, or produced.

Features

  • Modular easy-to-use design
  • 1-3 gas sensor capabilities
  • 3 configurable relays
  • 2 sensors max may be different sensors of the SC2 series, max 3 of them analog with  4-20 mA signals
  • Custom configuration dependent upon location and application
  • Warning buzzer/LED alarm, fault + operation option
  • Compatible with a wide range of BMS
  • Protocol for DGC-06 or Modbus protocol
  • Operating voltage input 100-240 VAC or 24VDC

Specifications

  • Measurement Range: 0-100ppm
  • Additional Ranges Available on request
    • 0-300ppm, 0-500ppm, 0-1,000ppm, 0-5,000ppm
  • Gas Type: Ammonia
  • Housing Type C/E: Polycarbonate
  • Installation: Wall Mounted
  • Knockouts for Cable Entry: Standard 6x M20/25
  • Ingress Protection: IP65
  • Temperature Range: -13°F to 140°F (-30°C to 50°C)
  • Humidity Range: 15-90% RH non-condensing
  • Storage Temperature: -4°F to 149°F (0° to 20°C)
  • Power Supply: 100-240 VAC or 24VDC
  • Power Consumption: 24 V DC | Max. 60 mA (1.5 VA), w/ sensor, w/o WAO
  • Alarm Relay (3): 5 A Dry Contact Configurable
  • Transistor Output (2): 24 V DC/0.1 A
  • Analog Input (2/3): 4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range
  • Analog Output Signal (1):
    • 2.4–< 4 mA = tolerable under range
    • 20–21.2 mA = tolerable over range 
    • ≥ 21,2 mA= error over range
    • ≤ 2,0 mA = fault
  • Dimensions: 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
  • Weight: 1.32 lbs. (0.6 kg)

Warranty

Options

  • SC2-E1110-A-P-00 | CO Digital Sensor for MSC2
  • SC2-E1130-B-P-00 | NO2 Digital Sensor for MSC2
  • SC2-E1194-A-P-00 | H2 Digital Sensor for MSC2
  • SC2-E1195-A2-P-00 | O2 Digital Sensor for MSC2
  • SC2-I464-B-P-00 | CO2 Digital Sensor for MSC2
  • MSC2-C-53432320A | Gaslab Fixed Multi- Gas
    Detector - w/ visual and audible
  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...