CozIR®-A 10,000ppm CO2 + RH/T Sensor
The CozIR®-A 10,000 ppm CO2 + temperature and % relative humidity sensor is designed to monitor carbon dioxide levels indoors. It is ideal for monitoring CO2 in buildings, schools, offices, or anywhere indoor air quality is important for the personal comfort of the occupants.
Features
- CO2, Temperature & %RH in a Single Sensor
- Low Power Consumption
- 2 Measurements Per Second
- Sensor life expectancy > 15 years
- Industry-Standard Serial Communication
Models
GC-0022 CozIR®-A 10,000 ppm CO2 + RH/T Sensor - for integration into high-volume OEM products. Contact us directly for wholesale pricing on large quantities of this sensor.
CM-0199 CozIR®-A 10,000 ppm CO2 + RH/T Development Kit - Easy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide, to configure the sensor, or for data logging.
CM-0047 Tube Cap Adapter - This adapter has been discontinued. If you are looking for a tube cap adapter, please contact us directly at Sales@CO2Meter.com. You MUST provide us with which sensor you have purchased for a proper solution.
Specifications
- CO2 Sensing Method: NDIR with Gold-plated optics
- Sample Method: Diffusion (Optional Sampling with Tube Cap)
- Auto Calibration Default (can be changed in software)
- CO2 Measurement Range: 0-10,000 ppm (parts per million)
- CO2 Measurement Rate: 0.5 sec / measurement
- CO2 Accuracy: ±50 ppm ± 3% of reading
- Resolution: 1ppm
- CO2 Pressure Dependence: 0.13% of reading per mm Hg
- CO2 Noise measurement: < 10 ppm
- Temperature Sensing Method: Bandgap
- Temperature Range: -0 to +55°C
- Temperature Accuracy: +/- 1°C within Range
- Humidity Sensing Method: Capacitive
- Humidity Range: 0 to 95% RH
- Humidity Accuracy: +/- 5% within Range
- Serial communication 9600/ 8/ 1/ n
- Analog output for CO2 concentration
- Sensor Life Expectancy: > 15 years
General Performance
- Warm-up Time: < 10 seconds (1.2s to first reading)
- Operating Conditions: -22°C to 55°C, 0-95% RH, 500 mbar to 40 bar
Electrical/Mechanical
- Power Input: 3.3-5.5VDC (3.3V recommended)
- Average Power Requirements: < 1.5mA @ 3.3V
- Peak current: 33mA
- Weight 20 grams
Warranty
- 90 days - See CO2Meter Terms and Conditions