Carbon Dioxide (CO2) Combustible Fixed Gas Detector (0-5000ppm)

Carbon Dioxide (CO2) Combustible Fixed Gas Detector (0-5000ppm)
Regular price $2,845.37

POs or wholesale quantity discounts click here

The Carbon Dioxide (CO2) Combustible Fixed Gas Detector (PX2-1-2-I464-C-01) is designed for continuous monitoring of CO2 gases between 0-5000ppm and vapors in hazardous areas of zones 1 and 2.

This detector is an explosion-proof fixed CO2 gas detector, based with a 4-20 mA / RS485 Modbus output signal, alarm and fault relays (all SIL2 certified) for monitoring the ambient air to detect toxic gases.

This solution is ideal for those industries that need protection amongst hazardous CO2 gases such as laboratories, garages, process rooms, combustion control rooms, refineries, gas stations, boiler rooms, confined spaces, and many others.

This device is also commonly purchased for cryogenic facilities, nitrogen applications, industrial, factory, dry ice freezing and much more.

Features

  • Modular industrial design, protection class IP66
  • Ex db: Ignition protection for zone 1 and 2
  • Ex nR: Ignition protection for zone 2
  • Fast and Precise CO2 Measurements 0-5000ppm
  • Compatible across a broad range of BMS
  • Device can be used independent of control systems
  • Individual configuration options available
  • Robust against dust, humidity, and high/low temperatures
  • Suitable for multiple industries and applications

Certifications

  • ATEX and IECEx certificates MSR-Electronic GmbH for electrical Ex protection
  • SIL2 safety functions 4–20 mA, RS-485 and relay
  • PX2-1 for zone 1 (and also suitable for zone 2):
  • Type “Ex db” protection flame-proof enclosure
  • PX2-2 for zone 2
  • Type “Ex nR” protection
  • Enclosure: Additional FM and CSA certificates for Class I, Div. 1

Models

  • PX2-1-2-E1110-C-01 - Gaslab Fixed Combustible Carbon Monoxide Detector
  • PX2-1-2-E1130-E-01 - Gaslab Fixed Combustible Nitrogen Dioxide Detector
  • PX2-1-2-E1194-A-01 - Gaslab Fixed Combustible Hydrogen Detector
  • PX2-1-2-E1195-A5-01 - Gaslab Fixed Combustible Oxygen Detector
  • PX2-1-2-P3400-A-01 - Gaslab Fixed Combustible Methane Detector
  • PX2-1-2-P3480-A-01 - Gaslab Fixed Combustible Propane Detector

Warranty

Specifications

  • Gas Type: Carbon Dioxide (CO2)
  • Range ppm: 0-5000ppm
  • Admissible Range for Calibration Zero PPM: ±10 % of measuring range
  • Admissible Range for Calibration Gain Test Gas: 30–120% of test gas
  • Temperature Range: -30 to +50°C
  • Storage Temperature Range: 0–20°C
  • Humidity Range: 15-90% RH
  • Pressure Range: 80–120 kPa
  • Reaction Time: ≤ 10 sec.
  • Run-in time2: 24 h
  • Flow Rate: 500 ml/min
  • Warm-up Time: 300 Sec.
  • Response Time: ≤ 200 Sec.
  • Life-time: >2 Years
    • Data Sheets

    • Manuals

    • Technical Documents

    • Videos

    • Additional Resources

    • Case Studies

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)

    "Easy to install, easy to set up, and easy calibration - just what I was looking for."

    - Phillip Farrar
    Water Plant Superintendent

    Read More Reviews...