🎄 Please Note: CO2Meter offices will be closed for the upcoming Holiday, 12/23-12/25, we will return refreshed and ready to serve you at 8:30AM ET on 12/26. We wish those celebrating a very Merry Christmas and a Happy New Year! 🎄

030-8-0006 K30 10,000 ppm CO2 Sensor

030-8-0006 K30 10,000ppm CO2 Sensor l CO2Meter
Regular price $113.79 Sale price

Compare at $145.89

POs or wholesale quantity discounts click here

The K30 10,000ppm CO2 Sensor Module (030-8-0006) is an industry favorite known for its low-cost, accuracy, long life and low maintenance. It is used in hundreds of HVAC and IAQ products and applications. In addition, this CO2 sensor is easy to program with several output options to meet virtually any OEM project specifications.

Features

  • Ideal for residential, commercial, HVAC or IAQ applications
  • Simple to install, pre-calibrated and ready-to-use
  • 2 analogue outputs, 2 digital outputs
  • Proven reliability, low cost, maintenance free

Models

  • K30 CO2 Sensor (030-8-0006) - for integration into high-volume OEM products.
  • K30 CO2 Sensor with Custom Outputs (030-8-0006-C) - Customize analog or digital outputs for your application. After ordering, email or fax the Custom Outputs PDF form and we will pre-configure your sensor’s settings. If the form is not received, your sensor will be delivered with default settings.
  • K30 CO2 Sensor Development Kit (CM-0024) - Easy to use, simply plug the sensor module into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide in real time or for data logging.
  • Sensor Development Kit (CM-200) - Easy to use, simply plug the sensor into the PCB and plug it into your PC via USB. Use our free GasLab® software to measure and graph carbon dioxide or use our library of source code on Github to build your own application or for OEM batch testing/configuration. Order sensors on this page, then order the Devkit here.

We recommend that all first-time users purchase either the CM-0024 or CM-200 Development Kit for fastest and easiest results.

Specifications

  • CO2 Measurement: non-dispersive infrared (NDIR)
  • Measurement Range: 0 – 10,000 ppm (0-5,000 ppm within specifications)
  • Rate of Measurement: every 2 seconds
  • Automatic Background Calibration (ABC): enabled unless specified
  • Response Time Diffusion: 20 seconds
  • Response Time Sample Draw: 2 seconds @ .5 l/min tube gas flow
  • Warm-up Time: < 1 min. (@ full specs < 15 min)
  • Outputs: 2 analog, 2 digital
  • Programmable Range: 0-10,000 ppm (custom configuration required)
  • Repeatability: ± 20 ppm ± 1 % of measured value within specifications
  • Accuracy: ± 30 ppm ± 3 % of measured value within specifications
  • Maintenance Interval: no maintenance required
  • Self-Diagnostics: complete function check at startup
  • Dimensions: 51 x 58 x 14 mm (Length x Width x approximate Height)
  • Sensor Life Expectancy: > 15 years

Conforms with Standards

  • Emission: EN61000-6-3:2001
  • Immunity: EN61000-6-2:2001
  • Compliant with ANSI/ASHRAE Standard 62.1-2022
  • Compliant with RESET grad B
  • Compliant with WELL Building Standard® (WELL v2™)
  • RoHS directive 2002/95/EG

Electrical / Mechanical

  • Power Input: 5.5-14 VDC, stabilized to within 10% (external protection circuits required)
  • Current Consumption: 40 mA average
  • Sampling Method: diffusion (tube cap optional)

Warranty

Datasheet Data Sheet (pdf)

CO2 sensor drawing Dimensional Drawings Tube Cap Adapter (pdf)

Senseair ISO Certification Senseair ISO Certification (pdf)

Custom Output

Custom Output Configuration Options (pdf)

Custom Outputs E-Mail Form (pdf)

Instructions:

1. Download the PDF form above and save to your hard drive.
2. Open the PDF and enter your values in the fields. Save.
3. Please specify in the form if you wish the ABC
(Automatic Background Calibration) on or off.
4. Please specify in the form if you want to program the
sensor for communication with RS-485.
5. Email as an attachment to sales@co2meter.com and reference your order code.
6. Select K30 1% Custom (030-8-0006-C) and complete your order.


Accessories

  • Gas Sensor Development Kit - CM-0024 designed to provide customers with an easy drop-in solution. Includes our free Gaslab data logging software. Sensor sold separately.
  • Tube Cap Adapter changes the sensor from reading CO2 in the air to a sample draw sensor. Use with a pump, tubing and filters to read CO2 levels in enclosed containers.
  • Sample Draw Pump Kit includes all the components you need with a sample draw sensor to create a closed CO2 measurement system.
  • Probe Enclosure. Includes hydrophobic filters, protects the sensor when used in hostile environments.
  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Based on 11 reviews
55%
(6)
45%
(5)
0%
(0)
0%
(0)
0%
(0)
J
Jerrold Billmyer
WOW! You don't know you need it until you have it

I am a retired chemist and live in a retirement community. Covid shut down a restaurant and even before the virus the air was so-so. Now I can measure the PPM of CO2 anywhere. The closed restaurant was terrible, but my calibration of outside air was 410PPM! Our committee now has evidence to back our arguments. I even verified the General Services tech's statement that our hall was set to input 100% outside air. It is even thought it is not cooled. At least it is fresh. Thank you CO2meter. Jerry

S
Stephen Rhodes
CO2 Sensor & Software

Sensor & Software worked great. A bit of a learning curve. Suggestions: You might want to inform your clients which sensors read just CO2 and not temp. or humidity. The CM-0024 just reads CO2. Also, the COM drivers was a bit difficult, but achievable. Finally, you might want to rethink your SCR-0039 screws. Finding a screw driver to fit the head was very difficult and the self tapping was so tight, it could possibly damage the sensor.

B
Burke Hales
K30

Good sensor

B
Burke Hales
K30

Good sensor

N
NATSUDA KHAMPA

K30 10,000ppm CO2 Sensor

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...