Fixed Hydrogen (H2) Gas Detector (0-1000ppm)

FixedHydrogen_H2_GasDetector_0-1000ppm_-co2meter
Regular price $2,907.08

POs or wholesale quantity discounts click here

The Fixed Hydrogen H2 Gas Detector (MSC2 + SC2-E1194-A-P-00) is designed to protect individuals near toxic and combustible gases. This fixed gas safety monitor measures H2 levels between 0-1000ppm and detects hazards in order to protect facilities from overexposure.

Fixed hydrogen gas detectors are critical due to use of Hydrogen as an energy carrier, throughout welding process, industrial manufacturing - or anywhere H2 is being used, stored, or produced.

Features

  • Modular easy-to-use design
  • 1-3 gas sensor capabilities
  • 3 configurable relays
  • 2 sensors max may be different sensors of the SC2 series, max 3 of them analog with  4-20 mA signals
  • Custom configuration dependent upon location and application
  • Warning buzzer/LED alarm, fault + operation option
  • Compatible with a wide range of BMS
  • Protocol for DGC-06 or Modbus protocol
  • Operating voltage input 100-240 VAC or 24VDC

Specifications

  • Measurement Range: 0-1000ppm
  • Gas: Hydrogen
  • Housing Type C/E: Polycarbonate
  • Installation: Wall Mounted
  • Knockouts for Cable Entry: Standard 6x M20/25
  • Ingress Protection: IP65
  • Temperature Range: -13°F to 140°F (-30°C to 50°C)
  • Humidity Range: 15-90% RH non-condensing
  • Storage Temperature: -4°F to 149°F (0° to 20°C)
  • Power Supply: 100-240 VAC or 24VDC
  • Power Consumption: 24 V DC | Max. 60 mA (1.5 VA), w/ sensor, w/o WAO
  • Alarm Relay (3): 5 A Dry Contact Configurable
  • Transistor Output (2): 24 V DC/0.1 A
  • Analog Input (2/3): 4-20mA, overload and short-circuit proof, input resistance 130 proportional, overload and short-circuit proof, load ≤ 500 4–20 mA = measuring range
  • Analog Output Signal (1):
    • 2.4–< 4 mA = tolerable under range
    • 20–21.2 mA = tolerable over range 
    • ≥ 21,2 mA= error over range
    • ≤ 2,0 mA = fault
  • Dimensions: 5.12 x 5.12 x 2.95 in. (130 x 130 x 75 mm)
  • Weight: 1.32 lbs. (0.6 kg)

Warranty

  • Data Sheets

  • Manuals

  • Technical Documents

  • Videos

  • Additional Resources

  • Case Studies

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

"Easy to install, easy to set up, and easy calibration - just what I was looking for."

- Phillip Farrar
Water Plant Superintendent

Read More Reviews...